Installation & Setup
Installing on a dual drain-line AC unit?Compare the Good, Better, and Best configurations
Good
Baseline Protection
Standard Sensor Switch on the main drain line, secondary line capped. Automatic overflow shutdown on the primary path, which is enough for lower-risk installs.
Better
Protection + Maintenance Access
Standard Sensor on the secondary line, AC Drain Wiz Mini on the main line for flush, air, and vacuum service without cutting PVC, with shutdown still covered.
Best
Dual-Line + Remote Monitoring
Standard Sensor on the secondary line, WiFi Sensor on the main. Both ports are protected, plus alerts and remote monitoring before shutdown.
Wiring a Sensor Switch?Standard and WiFi wire the same way. Where each pair lands, plus the full diagram and PDF
Control (24V AC)
AC unit safety circuit
The control pair: Safety Input and Safety Common.
Power (24V AC)
24V AC source
The power pair: Hot and Common.
Turn off power before installation. Confirm all connections are tight, insulated and wired according to the diagram before powering the system.